{"product_id":"bovie-specialist-pro-a1250s-120w-electrosurgical-generator-refurbished","title":"Bovie Specialist PRO A1250S 120W Electrosurgical Generator (Refurbished)","description":"\u003ch2\u003eCompact monopolar and bipolar electrosurgery for outpatient procedures\u003c\/h2\u003e\n\u003cp\u003eThe Bovie Specialist PRO A1250S is a 120-watt electrosurgical generator designed for physician offices, outpatient facilities, specialty practices, procedure rooms, and other clinical environments requiring monopolar and bipolar electrosurgical capability.\u003c\/p\u003e\n\u003cp\u003eThe generator provides five energy-delivery modes: Cut, Blend, Coagulation, Fulguration, and Bipolar. Its compact design delivers the functionality of a larger operating-room generator in a lower-powered platform suited to office-based and specialty procedures. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe A1250S must be operated only by qualified medical professionals trained in the electrosurgical technique and procedure being performed.\u003c\/p\u003e\n\u003ch2\u003eFive electrosurgical operating modes\u003c\/h2\u003e\n\u003cp\u003eThe Bovie Specialist PRO provides the following maximum output levels:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCut: 120 watts\u003c\/li\u003e\n\u003cli\u003eBlend: 90 watts\u003c\/li\u003e\n\u003cli\u003eCoagulation: 80 watts\u003c\/li\u003e\n\u003cli\u003eFulguration: 40 watts\u003c\/li\u003e\n\u003cli\u003eBipolar: 30 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese modes allow clinicians to select an appropriate energy-delivery method for monopolar cutting, blended cutting, coagulation, fulguration, and bipolar coagulation procedures.\u003c\/p\u003e\n\u003cp\u003ePower settings and operating modes must be selected according to the procedure, connected accessories, patient requirements, and the instructions provided in the manufacturer’s user guide. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eMonopolar and bipolar capability\u003c\/h2\u003e\n\u003cp\u003eThe A1250S supports both monopolar and bipolar electrosurgical procedures.\u003c\/p\u003e\n\u003cp\u003eMonopolar operation uses a compatible electrosurgical pencil or electrode together with an appropriate patient return electrode. Bipolar operation uses compatible bipolar forceps and accessories connected according to the manufacturer’s instructions.\u003c\/p\u003e\n\u003cp\u003eBipolar forceps, bipolar cables, footswitches, and specialized electrodes are available separately unless specifically included in the final configuration.\u003c\/p\u003e\n\u003ch2\u003eNeutral Electrode Monitoring\u003c\/h2\u003e\n\u003cp\u003eBovie NEM Neutral Electrode Monitoring technology monitors compatible split return electrodes during monopolar procedures.\u003c\/p\u003e\n\u003cp\u003eThe system is designed to identify return-electrode conditions that require attention and supports proper patient-return-electrode use. Clinical staff must still inspect the patient, cables, accessories, return electrode, and generator before every procedure.\u003c\/p\u003e\n\u003ch2\u003eDigital Error Detection\u003c\/h2\u003e\n\u003cp\u003eBovie DED Digital Error Detection continuously monitors generator functions and alerts the operator when the system detects an operating condition requiring attention.\u003c\/p\u003e\n\u003cp\u003eThe generator also includes self-test circuits, audible tones, isolated circuitry, and illuminated digital displays to support setup and operation. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eClear digital controls\u003c\/h2\u003e\n\u003cp\u003eLarge illuminated displays allow clinicians to view selected power settings, while raised push-button controls support rapid power adjustment.\u003c\/p\u003e\n\u003cp\u003eSeparate controls and indicators help distinguish the selected operating mode and output level. Audible activation tones provide an additional indication when electrosurgical energy is being delivered.\u003c\/p\u003e\n\u003ch2\u003eCompact clinical footprint\u003c\/h2\u003e\n\u003cp\u003eThe A1250S measures approximately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6 inches high\u003c\/li\u003e\n\u003cli\u003e10.25 inches wide\u003c\/li\u003e\n\u003cli\u003e12 inches deep\u003c\/li\u003e\n\u003cli\u003eLess than 14 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts compact dimensions allow it to be positioned on a procedure cart, equipment stand, countertop, or compatible mobile stand without requiring the space associated with a full-size operating-room generator. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eUniversal electrical compatibility\u003c\/h2\u003e\n\u003cp\u003eThe generator supports:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage: 100–240 VAC\u003c\/li\u003e\n\u003cli\u003eLine frequency: 50–60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput frequency: 350–600 kHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe appropriate hospital-grade power cord and electrical configuration must be used for the installation location.\u003c\/p\u003e\n\u003ch2\u003eElectrosurgical accessories\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer’s standard A1250S package lists a disposable push-button electrosurgical pencil, blade electrode, needle electrode, ball electrode, disposable split return electrodes, reusable grounding cords, power cords, and user documentation.\u003c\/p\u003e\n\u003cp\u003eFinal supplied contents are confirmed in the quotation.\u003c\/p\u003e\n\u003cp\u003eAdditional compatible accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonopolar footswitch\u003c\/li\u003e\n\u003cli\u003eFootswitch adapter\u003c\/li\u003e\n\u003cli\u003eBipolar forceps and cables\u003c\/li\u003e\n\u003cli\u003eAdditional disposable electrodes\u003c\/li\u003e\n\u003cli\u003eDermal electrodes\u003c\/li\u003e\n\u003cli\u003eLoop electrodes\u003c\/li\u003e\n\u003cli\u003eExtended ball electrodes\u003c\/li\u003e\n\u003cli\u003eReusable electrosurgical pencils\u003c\/li\u003e\n\u003cli\u003eSmoke-evacuation systems\u003c\/li\u003e\n\u003cli\u003eMobile equipment stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSurgical smoke management\u003c\/h2\u003e\n\u003cp\u003eElectrosurgical procedures may generate surgical smoke.\u003c\/p\u003e\n\u003cp\u003eA compatible smoke-evacuation system can be added separately to capture smoke near the source during applicable procedures. The smoke evacuator, tubing, filters, and related accessories are not included with the standard generator unless specified in the final quotation.\u003c\/p\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e120-watt electrosurgical generator\u003c\/li\u003e\n\u003cli\u003eMonopolar and bipolar operating capability\u003c\/li\u003e\n\u003cli\u003eFive energy-delivery modes\u003c\/li\u003e\n\u003cli\u003eCut output up to 120 watts\u003c\/li\u003e\n\u003cli\u003eBlend output up to 90 watts\u003c\/li\u003e\n\u003cli\u003eCoagulation output up to 80 watts\u003c\/li\u003e\n\u003cli\u003eFulguration output up to 40 watts\u003c\/li\u003e\n\u003cli\u003eBipolar output up to 30 watts\u003c\/li\u003e\n\u003cli\u003eBovie NEM Neutral Electrode Monitoring\u003c\/li\u003e\n\u003cli\u003eBovie DED Digital Error Detection\u003c\/li\u003e\n\u003cli\u003eLarge illuminated digital displays\u003c\/li\u003e\n\u003cli\u003eRaised push-button power controls\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test circuits\u003c\/li\u003e\n\u003cli\u003eAudible activation and alert tones\u003c\/li\u003e\n\u003cli\u003eIsolated circuitry\u003c\/li\u003e\n\u003cli\u003eFirst Come First Served output management\u003c\/li\u003e\n\u003cli\u003eCompact tabletop design\u003c\/li\u003e\n\u003cli\u003e100–240 VAC electrical compatibility\u003c\/li\u003e\n\u003cli\u003e50–60 Hz line-frequency compatibility\u003c\/li\u003e\n\u003cli\u003eLatex-free configuration\u003c\/li\u003e\n\u003cli\u003eFour-year manufacturer limited warranty \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eCommon Applications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003ePhysician-office procedures\u003c\/li\u003e\n\u003cli\u003eOutpatient minor procedures\u003c\/li\u003e\n\u003cli\u003eDermatology procedure rooms\u003c\/li\u003e\n\u003cli\u003eGynecology procedure rooms\u003c\/li\u003e\n\u003cli\u003ePodiatry practices\u003c\/li\u003e\n\u003cli\u003eUrgent-care procedure rooms\u003c\/li\u003e\n\u003cli\u003eSpecialty outpatient clinics\u003c\/li\u003e\n\u003cli\u003eAmbulatory treatment facilities\u003c\/li\u003e\n\u003cli\u003eGeneral tissue cutting\u003c\/li\u003e\n\u003cli\u003eElectrosurgical coagulation\u003c\/li\u003e\n\u003cli\u003eFulguration procedures\u003c\/li\u003e\n\u003cli\u003eBipolar coagulation procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitability for a specific procedure must be determined by a qualified medical professional according to training, clinical protocols, applicable regulations, and the manufacturer’s instructions.\u003c\/p\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cp\u003eManufacturer: Aspen Surgical\u003c\/p\u003e\n\u003cp\u003eBrand: Bovie\u003c\/p\u003e\n\u003cp\u003eProduct family: Specialist PRO\u003c\/p\u003e\n\u003cp\u003eManufacturer model: A1250S\u003c\/p\u003e\n\u003cp\u003eProduct type: High-frequency electrosurgical generator\u003c\/p\u003e\n\u003cp\u003eLifespan: Reusable\u003c\/p\u003e\n\u003cp\u003eSterilization status: Generator supplied non-sterile\u003c\/p\u003e\n\u003cp\u003eMonopolar capability: Yes\u003c\/p\u003e\n\u003cp\u003eBipolar capability: Yes\u003c\/p\u003e\n\u003cp\u003eMonopolar handpiece ports: One\u003c\/p\u003e\n\u003cp\u003eCut output: 120 W at 500 Ω\u003c\/p\u003e\n\u003cp\u003eBlend output: 90 W at 800 Ω\u003c\/p\u003e\n\u003cp\u003eCoagulation output: 80 W at 1,000 Ω\u003c\/p\u003e\n\u003cp\u003eFulguration output: 40 W at 1,000 Ω\u003c\/p\u003e\n\u003cp\u003eBipolar output: 30 W at 200 Ω\u003c\/p\u003e\n\u003cp\u003eOutput-frequency range: 350–600 kHz\u003c\/p\u003e\n\u003cp\u003eInput voltage: 100–240 VAC\u003c\/p\u003e\n\u003cp\u003eLine frequency: 50–60 Hz\u003c\/p\u003e\n\u003cp\u003eHeight: Approximately 6 inches \/ 15.2 cm\u003c\/p\u003e\n\u003cp\u003eWidth: Approximately 10.25 inches \/ 26 cm\u003c\/p\u003e\n\u003cp\u003eDepth: Approximately 12 inches \/ 30.5 cm\u003c\/p\u003e\n\u003cp\u003eWeight: Less than 14 lb \/ 6.5 kg\u003c\/p\u003e\n\u003cp\u003eReturn-electrode monitoring: Bovie NEM\u003c\/p\u003e\n\u003cp\u003eSystem monitoring: Bovie DED Digital Error Detection\u003c\/p\u003e\n\u003cp\u003eDisplay: Illuminated digital displays\u003c\/p\u003e\n\u003cp\u003eControls: Raised push-button power controls\u003c\/p\u003e\n\u003cp\u003eSafety testing: Automatic self-test circuits\u003c\/p\u003e\n\u003cp\u003eAudible indicators: Included\u003c\/p\u003e\n\u003cp\u003eLatex status: Latex-free\u003c\/p\u003e\n\u003cp\u003eWarranty: Four-year manufacturer limited warranty \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eManufacturer-Listed Standard Package\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eOne Bovie Specialist PRO A1250S electrosurgical generator\u003c\/li\u003e\n\u003cli\u003eOne ESP1 disposable push-button electrosurgical pencil\u003c\/li\u003e\n\u003cli\u003eOne ES01 disposable blade electrode\u003c\/li\u003e\n\u003cli\u003eOne ES02 disposable needle electrode\u003c\/li\u003e\n\u003cli\u003eOne ES20 3\/16-inch disposable ball electrode\u003c\/li\u003e\n\u003cli\u003eFive ESRE disposable split return electrodes\u003c\/li\u003e\n\u003cli\u003eTwo A1252C reusable grounding cords\u003c\/li\u003e\n\u003cli\u003eHospital-grade power cord\u003c\/li\u003e\n\u003cli\u003eUser guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFinal supplied contents are confirmed during quotation. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eAvailable Accessories\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eSmoke Shark II smoke evacuator\u003c\/li\u003e\n\u003cli\u003eSmart Shark remote activation switch\u003c\/li\u003e\n\u003cli\u003eMonopolar footswitch\u003c\/li\u003e\n\u003cli\u003eFootswitch adapter\u003c\/li\u003e\n\u003cli\u003eBipolar forceps\u003c\/li\u003e\n\u003cli\u003eBipolar connecting cable\u003c\/li\u003e\n\u003cli\u003eSplit return electrodes\u003c\/li\u003e\n\u003cli\u003eDisposable electrosurgical pencils\u003c\/li\u003e\n\u003cli\u003eReusable electrosurgical pencils\u003c\/li\u003e\n\u003cli\u003eBlade electrodes\u003c\/li\u003e\n\u003cli\u003eNeedle electrodes\u003c\/li\u003e\n\u003cli\u003eBall electrodes\u003c\/li\u003e\n\u003cli\u003eDermal-loop electrodes\u003c\/li\u003e\n\u003cli\u003eLLETZ and LEEP electrodes\u003c\/li\u003e\n\u003cli\u003eMobile equipment stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccessories are sold separately unless listed in the final product configuration.\u003c\/p\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eWhat procedures can the Bovie Specialist PRO support?\u003c\/h2\u003e\n\u003cp\u003eThe generator supports monopolar Cut, Blend, Coagulation, and Fulguration modes together with Bipolar coagulation. A qualified clinician must determine whether it is appropriate for the specific procedure.\u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum cutting output?\u003c\/h2\u003e\n\u003cp\u003eThe maximum Cut output is 120 watts at a rated load of 500 ohms.\u003c\/p\u003e\n\u003ch2\u003eDoes the generator support bipolar procedures?\u003c\/h2\u003e\n\u003cp\u003eYes. The A1250S provides a Bipolar output of up to 30 watts. Compatible bipolar forceps and connecting accessories may be required separately.\u003c\/p\u003e\n\u003ch2\u003eDoes it include return-electrode monitoring?\u003c\/h2\u003e\n\u003cp\u003eYes. Bovie NEM technology monitors compatible split patient return electrodes during monopolar operation.\u003c\/p\u003e\n\u003ch2\u003eWhat is Digital Error Detection?\u003c\/h2\u003e\n\u003cp\u003eBovie DED monitors generator functions and alerts the operator when an operating condition requires attention.\u003c\/p\u003e\n\u003ch2\u003eDoes the generator perform a self-test?\u003c\/h2\u003e\n\u003cp\u003eYes. The unit incorporates self-test circuits that evaluate generator functions during startup.\u003c\/p\u003e\n\u003ch2\u003eAre accessories included?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer’s standard package lists an electrosurgical pencil, three electrode styles, five split return electrodes, two reusable grounding cords, a power cord, and user documentation. Final contents are confirmed in the quotation.\u003c\/p\u003e\n\u003ch2\u003eIs a footswitch included?\u003c\/h2\u003e\n\u003cp\u003eA footswitch is not listed in the standard A1250S package. Compatible monopolar footswitches and an adapter are available separately.\u003c\/p\u003e\n\u003ch2\u003eIs a smoke evacuator included?\u003c\/h2\u003e\n\u003cp\u003eNo. A compatible smoke-evacuation system is available separately.\u003c\/p\u003e\n\u003ch2\u003eDoes it operate on standard U.S. electrical power?\u003c\/h2\u003e\n\u003cp\u003eThe generator accepts 100–240 VAC at 50–60 Hz. The appropriate hospital-grade power cord must be used.\u003c\/p\u003e\n\u003ch2\u003eHow large is the generator?\u003c\/h2\u003e\n\u003cp\u003eIt measures approximately 6 inches high, 10.25 inches wide, and 12 inches deep and weighs less than 14 lb.\u003c\/p\u003e\n\u003ch2\u003eIs the generator supplied sterile?\u003c\/h2\u003e\n\u003cp\u003eNo. The generator is a reusable, non-sterile device. Sterile and reusable accessories must be handled according to their individual instructions.\u003c\/p\u003e\n\u003ch2\u003eWhat warranty is provided?\u003c\/h2\u003e\n\u003cp\u003eThe Bovie Specialist PRO is backed by a four-year manufacturer limited warranty.\u003c\/p\u003e\n\u003ch2\u003eWho should operate the generator?\u003c\/h2\u003e\n\u003cp\u003eThe generator is intended for use only by qualified medical professionals trained in the electrosurgical technique and procedure being performed. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eDocuments and Downloads\u003c\/h1\u003e\n\u003ch2\u003eBovie Specialist PRO A1250S User Guide — PDF\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/cdn.brandfolder.io\/TVDZACS7\/at\/fqrn8xrz9rc38hcscbqphkg7\/MC-55-237-001_USER_GUIDE__BOVIE_A1250S_Rev_5-EN-2.pdf\"\u003ehttps:\/\/cdn.brandfolder.io\/TVDZACS7\/at\/fqrn8xrz9rc38hcscbqphkg7\/MC-55-237-001_USER_GUIDE__BOVIE_A1250S_Rev_5-EN-2.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eBovie Specialist PRO A1250S Service Guide — PDF\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" class=\"decorated-link\"\u003ehttps:\/\/cdn.brandfolder.io\/TVDZACS7\/at\/6n3hgcqtk67b9t5rswbcqn\/MC-55-237-002_SERVICE_GUIDE__BOVIE_A1250S_Rev_6-EN.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eBovie Electrosurgical Generator Brochure — PDF\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/cdn.brandfolder.io\/TVDZACS7\/at\/kh89k65g9znmn7k7xx33spj\/Bovie_Surgical_Generator_Brochure_FC_05082023_v1.pdf\"\u003ehttps:\/\/cdn.brandfolder.io\/TVDZACS7\/at\/kh89k65g9znmn7k7xx33spj\/Bovie_Surgical_Generator_Brochure_FC_05082023_v1.pdf\u003c\/a\u003e\u003c\/p\u003e","brand":"Soma Tech International","offers":[{"title":"Default Title","offer_id":42352648126519,"sku":"BB-ST-ESU-0070-FG","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/2167\/4039\/files\/images_2982c24b-2139-4846-be73-cb079c7bb074.jpg?v=1785941773","url":"https:\/\/bigbenmedical.com\/products\/bovie-specialist-pro-a1250s-120w-electrosurgical-generator-refurbished","provider":"Big Ben Medical Supplies","version":"1.0","type":"link"}