{"product_id":"btnx-rapid-response-u121s-urine-analyzer-with-barcode-reader","title":"BTNX Rapid Response U121S Urine Analyzer with Barcode Reader","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eAutomated urinalysis interpretation for faster point-of-care testing\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe BTNX Rapid Response U121S Urine Analyzer is a compact point-of-care instrument designed to automatically read and interpret compatible Rapid Response urinalysis reagent strips.\u003c\/p\u003e\n\u003cp\u003eThe analyzer uses reflectance photometry to evaluate color changes on the reagent strip, helping clinical staff produce more standardized results than visual strip interpretation alone. It can read, store, display, and print urinalysis results, supporting higher-throughput testing in urgent-care centers, physician offices, occupational-health clinics, outpatient facilities, and other professional healthcare settings. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe selected \u003ccode\u003eUA-U121S\u003c\/code\u003e configuration includes a barcode reader for scanning reagent-strip canister codes and entering patient identification information. This helps reduce manual data-entry steps and supports more controlled association of test information with the correct strip type and patient record. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eResults in approximately 60 seconds\u003c\/h2\u003e\n\u003cp\u003eThe analyzer uses a one-minute strip incubation time. In single-test mode, it can process up to 60 tests per hour. Continuous-test mode supports sequential strip processing at a listed throughput of up to 120 tests per hour.\u003c\/p\u003e\n\u003cp\u003eThese capabilities make the U121S suitable for clinics that perform regular urinalysis testing and want to reduce manual timing and visual color-comparison variability. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eBuilt-in result storage and printing\u003c\/h2\u003e\n\u003cp\u003eThe U121S includes an internal thermal printer for producing paper result records at the point of care.\u003c\/p\u003e\n\u003cp\u003eThe analyzer can store the latest 2,000 results in its internal database. Staff can search records by test number and date, review previous results on the analyzer, and print stored records when needed. When the database reaches capacity, the oldest record is replaced by the newest result. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable printer settings include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic or manual printing\u003c\/li\u003e\n\u003cli\u003eInternal or compatible external printer selection\u003c\/li\u003e\n\u003cli\u003eAdjustable print darkness\u003c\/li\u003e\n\u003cli\u003eStandard or expanded font\u003c\/li\u003e\n\u003cli\u003eOne to three printed copies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBarcode-assisted strip and patient identification\u003c\/h2\u003e\n\u003cp\u003eThe included barcode reader can be used to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScan reagent-strip canister codes\u003c\/li\u003e\n\u003cli\u003eConfirm the selected strip configuration\u003c\/li\u003e\n\u003cli\u003eEnter patient identification information\u003c\/li\u003e\n\u003cli\u003eEnter operator passcodes where configured\u003c\/li\u003e\n\u003cli\u003eReduce manual canister-code entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe analyzer should be used only with compatible Rapid Response urinalysis reagent strips and the correct canister barcode. The selected strip type in the analyzer must match the strip being tested. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eRoutine, STAT, and quality-control modes\u003c\/h2\u003e\n\u003cp\u003eThe analyzer supports three testing modes:\u003c\/p\u003e\n\u003cp\u003eRoutine Mode for standard patient testing\u003c\/p\u003e\n\u003cp\u003eSTAT Mode for urgent testing workflows\u003c\/p\u003e\n\u003cp\u003eQC Mode for testing positive and negative urine controls\u003c\/p\u003e\n\u003cp\u003eThe system also supports scheduled quality-control lockout intervals. Facilities can configure QC requirements every eight hours, daily, weekly, or monthly. When QC lockout is enabled, the analyzer can require an acceptable control test before additional patient testing proceeds. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eOperator access and configurable settings\u003c\/h2\u003e\n\u003cp\u003eAuthorized users can configure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStrip type\u003c\/li\u003e\n\u003cli\u003eRoutine, STAT, or QC mode\u003c\/li\u003e\n\u003cli\u003eTest number\u003c\/li\u003e\n\u003cli\u003eSingle or continuous testing\u003c\/li\u003e\n\u003cli\u003eOperator identification\u003c\/li\u003e\n\u003cli\u003eConventional or SI units\u003c\/li\u003e\n\u003cli\u003ePrinter settings\u003c\/li\u003e\n\u003cli\u003eSound prompts\u003c\/li\u003e\n\u003cli\u003eBarcode-reader operation\u003c\/li\u003e\n\u003cli\u003eLanguage\u003c\/li\u003e\n\u003cli\u003eDate and time\u003c\/li\u003e\n\u003cli\u003eAutomatic test-number reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe analyzer also supports administrator and operator login functions. This can help clinics limit access to configuration settings while allowing approved staff to perform and review tests. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eData-transfer capabilities\u003c\/h2\u003e\n\u003cp\u003eThe analyzer includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard RS232C port\u003c\/li\u003e\n\u003cli\u003eUSB port\u003c\/li\u003e\n\u003cli\u003eExternal-printer port\u003c\/li\u003e\n\u003cli\u003eInternal thermal printer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer’s documentation describes data transfer through USB or RS232C connections. However, direct EMR, EHR, or LIS integration is not confirmed for the standard IMCO configuration.\u003c\/p\u003e\n\u003ch2\u003eCompatible 10-parameter testing\u003c\/h2\u003e\n\u003cp\u003eThe recommended consumable for the initial Big Ben configuration is:\u003c\/p\u003e\n\u003cp\u003eBTNX Rapid Response 10-Parameter Urinalysis Reagent Strips\u003c\/p\u003e\n\u003cp\u003eSKU: \u003ccode\u003eU10.1-1S100\u003c\/code\u003e\u003c\/p\u003e\n\u003cp\u003eQuantity: 100 strips per canister\u003c\/p\u003e\n\u003cp\u003eThe 10-parameter strips evaluate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLeukocytes\u003c\/li\u003e\n\u003cli\u003eNitrite\u003c\/li\u003e\n\u003cli\u003eUrobilinogen\u003c\/li\u003e\n\u003cli\u003eProtein\u003c\/li\u003e\n\u003cli\u003epH\u003c\/li\u003e\n\u003cli\u003eBlood\u003c\/li\u003e\n\u003cli\u003eSpecific gravity\u003c\/li\u003e\n\u003cli\u003eKetones\u003c\/li\u003e\n\u003cli\u003eBilirubin\u003c\/li\u003e\n\u003cli\u003eGlucose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe reagent strips are intended for qualitative and semi-quantitative evaluation of urine analytes and should be used according to their product insert and the analyzer instructions. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eProfessional in vitro diagnostic use\u003c\/h2\u003e\n\u003cp\u003eThe U121S is intended for professional in vitro diagnostic use with compatible Rapid Response urinalysis reagent strips.\u003c\/p\u003e\n\u003cp\u003eThe analyzer and strips may support the general evaluation of health and aid healthcare professionals in evaluating metabolic, systemic, endocrine, kidney, and urinary-tract conditions. Results must be interpreted alongside the patient’s clinical presentation and other diagnostic findings. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCLIA-waived configuration\u003c\/h2\u003e\n\u003cp\u003eIMCO lists the selected \u003ccode\u003eUA-U121S\u003c\/code\u003e configuration as CLIA waived. The FDA database identifies the BTNX Rapid Response U120S Urine Analyzer Test System as waived for multiple listed urine dipstick analytes when used as an authorized test system. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe clinic must still:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHold the appropriate CLIA certificate\u003c\/li\u003e\n\u003cli\u003eUse an approved analyzer-and-strip combination\u003c\/li\u003e\n\u003cli\u003eFollow the current product instructions\u003c\/li\u003e\n\u003cli\u003ePerform required quality control\u003c\/li\u003e\n\u003cli\u003eMaintain staff training and test records\u003c\/li\u003e\n\u003cli\u003eConfirm the regulatory status of each test configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated interpretation of urinalysis reagent strips\u003c\/li\u003e\n\u003cli\u003eReflectance-photometer measurement principle\u003c\/li\u003e\n\u003cli\u003eApproximately 60-second strip incubation\u003c\/li\u003e\n\u003cli\u003eUp to 60 tests per hour in single-test mode\u003c\/li\u003e\n\u003cli\u003eUp to 120 tests per hour in continuous mode\u003c\/li\u003e\n\u003cli\u003eIncluded barcode reader\u003c\/li\u003e\n\u003cli\u003eReagent-canister barcode recognition\u003c\/li\u003e\n\u003cli\u003ePatient ID entry\u003c\/li\u003e\n\u003cli\u003eInternal thermal printer\u003c\/li\u003e\n\u003cli\u003eTwo printer-paper rolls included\u003c\/li\u003e\n\u003cli\u003eStorage for the latest 2,000 results\u003c\/li\u003e\n\u003cli\u003eRoutine, STAT, and QC testing modes\u003c\/li\u003e\n\u003cli\u003eConfigurable QC lockout\u003c\/li\u003e\n\u003cli\u003eOperator and administrator access settings\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test at startup\u003c\/li\u003e\n\u003cli\u003eConventional and SI reporting units\u003c\/li\u003e\n\u003cli\u003eUSB and RS232C communication ports\u003c\/li\u003e\n\u003cli\u003eExternal-printer connection\u003c\/li\u003e\n\u003cli\u003eCompact benchtop design\u003c\/li\u003e\n\u003cli\u003eCLIA-waived test-system status for authorized configurations\u003c\/li\u003e\n\u003cli\u003eOne-year analyzer warranty stated in the manufacturer manual \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eCommon Clinical Applications\u003c\/h1\u003e\n\u003cp\u003eThe BTNX U121S may support professional point-of-care urinalysis in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUrgent-care clinics\u003c\/li\u003e\n\u003cli\u003ePrimary-care practices\u003c\/li\u003e\n\u003cli\u003eFamily medicine clinics\u003c\/li\u003e\n\u003cli\u003eOccupational-health clinics\u003c\/li\u003e\n\u003cli\u003eUrology practices\u003c\/li\u003e\n\u003cli\u003eInternal medicine clinics\u003c\/li\u003e\n\u003cli\u003eCommunity-health centers\u003c\/li\u003e\n\u003cli\u003eOutpatient medical facilities\u003c\/li\u003e\n\u003cli\u003eLong-term care settings\u003c\/li\u003e\n\u003cli\u003ePhysician-office laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCommon testing workflows may include evaluation associated with urinary symptoms, hydration status, metabolic conditions, kidney-related findings, and routine clinical screening.\u003c\/p\u003e\n\u003cp\u003eThe analyzer does not independently diagnose a medical condition. Results require interpretation by qualified healthcare professionals.\u003c\/p\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cp\u003eManufacturer: BTNX Inc.\u003c\/p\u003e\n\u003cp\u003eBrand: Rapid Response\u003c\/p\u003e\n\u003cp\u003eProduct model: U121S\u003c\/p\u003e\n\u003cp\u003eIMCO item number: UA-U121S\u003c\/p\u003e\n\u003cp\u003eProduct type: Automated urine reagent-strip analyzer\u003c\/p\u003e\n\u003cp\u003eSample type: Human urine\u003c\/p\u003e\n\u003cp\u003eMeasurement method: Reflectance photometry\u003c\/p\u003e\n\u003cp\u003eDetector: Photosensitive diode\u003c\/p\u003e\n\u003cp\u003eStrip incubation time: One minute\u003c\/p\u003e\n\u003cp\u003eTime to result: Approximately 60 seconds\u003c\/p\u003e\n\u003cp\u003eSingle-test throughput: Up to 60 tests per hour\u003c\/p\u003e\n\u003cp\u003eContinuous-test throughput: Up to 120 tests per hour\u003c\/p\u003e\n\u003cp\u003eInternal memory: Latest 2,000 results\u003c\/p\u003e\n\u003cp\u003eDetection wavelengths: 525 nm and 635 nm\u003c\/p\u003e\n\u003cp\u003eTesting modes: Routine, STAT, and QC\u003c\/p\u003e\n\u003cp\u003ePrinter: Built-in thermal printer\u003c\/p\u003e\n\u003cp\u003eBarcode reader: Included with the U121S configuration\u003c\/p\u003e\n\u003cp\u003eCommunication ports: USB, RS232C, and external-printer port\u003c\/p\u003e\n\u003cp\u003ePower requirement: 100–240 V AC, 50\/60 Hz, 35 VA\u003c\/p\u003e\n\u003cp\u003eOperating temperature: 0°C–40°C \/ 32°F–104°F\u003c\/p\u003e\n\u003cp\u003eOperating humidity: Up to 85% relative humidity, non-condensing\u003c\/p\u003e\n\u003cp\u003eRecommended strip operating temperature: 15°C–30°C \/ 59°F–86°F\u003c\/p\u003e\n\u003cp\u003eDimensions: Approximately 10.8 × 7.2 × 5.5 inches\u003c\/p\u003e\n\u003cp\u003eMetric dimensions: Approximately 27.5 × 18.3 × 13.9 cm\u003c\/p\u003e\n\u003cp\u003eWeight: Approximately 4.1 lb. \/ 1.85 kg\u003c\/p\u003e\n\u003cp\u003eDisplay dimensions: Approximately 4.2 × 2.6 inches\u003c\/p\u003e\n\u003cp\u003eWarranty: One year for the analyzer, subject to the manufacturer’s warranty conditions \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat Is Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eOne Rapid Response urine analyzer\u003c\/li\u003e\n\u003cli\u003eOne power cord\u003c\/li\u003e\n\u003cli\u003eTwo printer-paper rolls\u003c\/li\u003e\n\u003cli\u003eOne RS232C serial splitter cable\u003c\/li\u003e\n\u003cli\u003eOne barcode scanner\u003c\/li\u003e\n\u003cli\u003eInstruction manual \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUrinalysis reagent strips, urine controls, specimen cups, replacement printer paper, data-transfer accessories, and external printers should not be advertised as included unless confirmed in the final IMCO quotation.\u003c\/p\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eWhat does the BTNX U121S do?\u003c\/h2\u003e\n\u003cp\u003eThe U121S automatically reads compatible Rapid Response urinalysis reagent strips using reflectance photometry. It displays, stores, and prints the interpreted results. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHow quickly does it provide results?\u003c\/h2\u003e\n\u003cp\u003eThe analyzer uses a one-minute strip incubation time. BTNX lists a result time of approximately 60 seconds. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHow many tests can it process?\u003c\/h2\u003e\n\u003cp\u003eIt can process up to 60 tests per hour in single-test mode and up to 120 tests per hour in continuous mode. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDoes the analyzer include a barcode reader?\u003c\/h2\u003e\n\u003cp\u003eYes. The \u003ccode\u003eUA-U121S\u003c\/code\u003e package includes a barcode reader for canister-code recognition and patient ID entry. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDoes it include an internal printer?\u003c\/h2\u003e\n\u003cp\u003eYes. The system includes an internal thermal printer and two printer-paper rolls. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHow many results can it store?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer manual states that the analyzer stores the latest 2,000 results. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eWhich reagent strips should be ordered with it?\u003c\/h2\u003e\n\u003cp\u003eFor the initial Big Ben configuration, use the BTNX 10-Parameter Urinalysis Reagent Strips, SKU \u003ccode\u003eU10.1-1S100\u003c\/code\u003e, supplied as 100 strips per canister.\u003c\/p\u003e\n\u003cp\u003eAlways confirm that the strip canister, barcode, analyzer setting, and current instructions identify the strip as compatible before use. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eAre reagent strips included with the analyzer?\u003c\/h2\u003e\n\u003cp\u003eNo reagent strips are listed among the standard contents of \u003ccode\u003eUA-U121S\u003c\/code\u003e. They should be purchased separately.\u003c\/p\u003e\n\u003ch2\u003eIs this analyzer CLIA waived?\u003c\/h2\u003e\n\u003cp\u003eIMCO identifies the configuration as CLIA waived. The FDA database lists the BTNX Rapid Response U120S Urine Analyzer Test System as waived for authorized urine dipstick analytes. Waived status depends on using the approved test system and following its instructions exactly. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDoes a clinic still need a CLIA certificate?\u003c\/h2\u003e\n\u003cp\u003eYes. A clinic performing CLIA-waived testing generally needs the appropriate CLIA Certificate of Waiver or another applicable CLIA certificate.\u003c\/p\u003e\n\u003ch2\u003eDoes the analyzer support quality-control testing?\u003c\/h2\u003e\n\u003cp\u003eYes. It includes a dedicated QC mode and configurable QC lockout intervals. Clinics must use compatible urine controls and follow the manufacturer’s instructions and facility procedures. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCan the analyzer connect to an EMR or EHR?\u003c\/h2\u003e\n\u003cp\u003eThe analyzer has USB and RS232C data-transfer capabilities, but direct EMR or EHR integration is not verified for the standard configuration. Confirm compatibility, interface requirements, software, and implementation support before making a connectivity claim. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCan staff visually interpret the same strips?\u003c\/h2\u003e\n\u003cp\u003eThe selected BTNX 10-parameter strips may support visual reading or compatible analyzer reading. However, clinics should follow the exact instructions supplied with the strips and analyzer. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat maintenance is required?\u003c\/h2\u003e\n\u003cp\u003eThe strip holder and testing area require routine cleaning. The manufacturer manual provides daily cleaning, general cleaning, sterilization, printer-paper replacement, and troubleshooting procedures. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eWhat warranty is included?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer manual states a one-year warranty for the original analyzer against defects in materials and workmanship, subject to the stated exclusions and registration requirements. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eDocuments and Downloads\u003c\/h1\u003e\n\u003ch2\u003eRapid Response U120S\/U121S Urine Analyzer Instruction Manual — PDF\u003c\/h2\u003e\n\u003cp\u003eThe official U121S product page links to this manual. It covers analyzer setup, barcode operation, testing, quality control, result storage, printing, cleaning, troubleshooting, specifications, and warranty.\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/strategicstrike.blob.core.windows.net\/lochness-products\/resources\/U120S%20User%20Manual%20%28EN%29%20-User%20Manual-245.pdf\"\u003ehttps:\/\/strategicstrike.blob.core.windows.net\/lochness-products\/resources\/U120S%20User%20Manual%20%28EN%29%20-User%20Manual-245.pdf\u003c\/a\u003e\u003c\/p\u003e","brand":"BTNX Inc.","offers":[{"title":"Default Title","offer_id":42351040299063,"sku":"BB-BT121S","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/2167\/4039\/files\/images_f9f020d1-a123-4620-b0b5-c9ba98cdf2a0.jpg?v=1785857308","url":"https:\/\/bigbenmedical.com\/products\/btnx-rapid-response-u121s-urine-analyzer-with-barcode-reader","provider":"Big Ben Medical Supplies","version":"1.0","type":"link"}