{"product_id":"stryker-940-cast-cutter-system-with-986-castvac-refurbished","title":"Stryker 940 Cast Cutter System with 986 CastVac — Refurbished","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe refurbished Stryker 940 Cast Cutter System with Stryker 986 CastVac provides an integrated solution for sectioning and removing plaster and synthetic orthopedic casts while collecting dry cast debris during use.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe system combines the Stryker 940 two-speed cast cutter with the mobile Stryker 986 CastVac dust-extraction unit. The cast cutter can operate at standard speed for routine cast removal or high speed for thicker cast materials. When connected to the CastVac, the vacuum can activate automatically when the cast cutter is operated.\u003c\/p\u003e\n\u003cp\u003eThis refurbished system is suitable for orthopedic clinics, urgent care centers, emergency departments, hospitals, fracture clinics, sports medicine practices, and outpatient medical facilities.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete cast-removal system with cutter and vacuum\u003c\/li\u003e\n\u003cli\u003eStryker 940 two-speed cast cutter\u003c\/li\u003e\n\u003cli\u003eStandard-speed and high-speed operating modes\u003c\/li\u003e\n\u003cli\u003eDesigned to section plaster and synthetic casts\u003c\/li\u003e\n\u003cli\u003eErgonomic handheld cast cutter\u003c\/li\u003e\n\u003cli\u003eQuick-connect vacuum interface\u003c\/li\u003e\n\u003cli\u003eCan operate from a\u003c\/li\u003e\n\u003cli\u003eQuick-connect vacuum interface\u003c\/li\u003e\n\u003cli\u003eCan operate from a compatible wall outlet or the CastVac power outlet\u003c\/li\u003e\n\u003cli\u003eStryker 986 CastVac dust-extraction system\u003c\/li\u003e\n\u003cli\u003eAutomatic vacuum activation when the connected cast cutter is operated\u003c\/li\u003e\n\u003cli\u003eThree-position CastVac power control\u003c\/li\u003e\n\u003cli\u003eMobile five-wheel stand\u003c\/li\u003e\n\u003cli\u003eLockable casters for positioning and stability\u003c\/li\u003e\n\u003cli\u003eRemovable dust-collection canister lid\u003c\/li\u003e\n\u003cli\u003eSwivel vacuum-hose mount\u003c\/li\u003e\n\u003cli\u003e8-foot \/ 2.4-meter vacuum hose\u003c\/li\u003e\n\u003cli\u003eCompatible with approved Stryker cast-cutter blades\u003c\/li\u003e\n\u003cli\u003eRefurbished, inspected, tested, and restored by the equipment supplier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStryker 940 Cast Cutter\u003c\/li\u003e\n\u003cli\u003eStryker 986 CastVac\u003c\/li\u003e\n\u003cli\u003eMobile CastVac stand\u003c\/li\u003e\n\u003cli\u003eVacuum hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe exact package contents must be confirmed before order completion. Cast-cutter blades, blade tools, replacement filters, power cords, manuals, and other accessories are included only when specifically stated in the final quotation.\u003c\/p\u003e\n\u003ch3\u003eStryker 940 Cast Cutter Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Stryker\u003c\/li\u003e\n\u003cli\u003eModel: 940\u003c\/li\u003e\n\u003cli\u003eEquipment Type: Powered orthopedic cast cutter\u003c\/li\u003e\n\u003cli\u003eIntended Material: Plaster and synthetic casts\u003c\/li\u003e\n\u003cli\u003eOperating Modes: Standard speed, standby, and high speed\u003c\/li\u003e\n\u003cli\u003eElectrical Input: 100–120V, 50–60Hz, 1.5A\u003c\/li\u003e\n\u003cli\u003eStandard Speed at 120V: Approximately 10,700 cycles per minute\u003c\/li\u003e\n\u003cli\u003eHigh Speed at 120V: Approximately 15,900 cycles per minute\u003c\/li\u003e\n\u003cli\u003eBlade Excursion: 0.125 inch \/ 3.2 mm\u003c\/li\u003e\n\u003cli\u003eLength: Approximately 10 inches \/ 25.4 cm\u003c\/li\u003e\n\u003cli\u003eHeight: Approximately 3 inches \/ 7.6 cm\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 2.8 lb \/ 1.3 kg\u003c\/li\u003e\n\u003cli\u003ePower Cord Length: Approximately 10.25 feet \/ 3.1 meters\u003c\/li\u003e\n\u003cli\u003eDuty Cycle: Up to 15 minutes of operation followed by a 20-minute rest period\u003c\/li\u003e\n\u003cli\u003eElectrical Classification: Class II, Type BF applied part\u003c\/li\u003e\n\u003cli\u003eIngress Protection: IPX0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStryker 986 CastVac Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Stryker\u003c\/li\u003e\n\u003cli\u003eModel: 986 CastVac\u003c\/li\u003e\n\u003cli\u003eEquipment Type: Dry cast-debris vacuum system\u003c\/li\u003e\n\u003cli\u003eConfiguration: Mobile stand\u003c\/li\u003e\n\u003cli\u003eElectrical Input: 100–120V, 50–60Hz, 8.5A\u003c\/li\u003e\n\u003cli\u003ePower Cord: Hospital-grade NEMA plug\u003c\/li\u003e\n\u003cli\u003eVacuum Hose Length: 8 feet \/ 2.4 meters\u003c\/li\u003e\n\u003cli\u003eCanister Height: Approximately 24.4 inches \/ 62 cm\u003c\/li\u003e\n\u003cli\u003eCanister Diameter: Approximately 8.75 inches \/ 22.2 cm\u003c\/li\u003e\n\u003cli\u003eCanister Weight: Approximately 13.5 lb \/ 6.1 kg\u003c\/li\u003e\n\u003cli\u003eOperating Mode: Continuous\u003c\/li\u003e\n\u003cli\u003eElectrical Classification: Class I\u003c\/li\u003e\n\u003cli\u003eIngress Protection: IPX0\u003c\/li\u003e\n\u003cli\u003eVacuum Application: Dry cast debris only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Cast-Cutter Blades\u003c\/h3\u003e\n\u003cp\u003eThe Stryker 940 supports approved blades selected according to the cast material:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIon-nitrided blade for plaster or synthetic casts\u003c\/li\u003e\n\u003cli\u003eStainless-steel blade for plaster casts\u003c\/li\u003e\n\u003cli\u003eTitanium-nitrided blade for synthetic casts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\u003cp\u003eThe system may be used by trained healthcare professionals for removing orthopedic casts in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOrthopedic clinics\u003c\/li\u003e\n\u003cli\u003eFracture clinics\u003c\/li\u003e\n\u003cli\u003eUrgent care centers\u003c\/li\u003e\n\u003cli\u003eEmergency departments\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eSports medicine practices\u003c\/li\u003e\n\u003cli\u003eOutpatient surgery centers\u003c\/li\u003e\n\u003cli\u003eRehabilitation facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRefurbished Condition\u003c\/h3\u003e\n\u003cp\u003eThis product is offered as refurbished medical equipment. The supplier states that refurbished equipment is technically and cosmetically restored, inspected, tested, and evaluated before shipment.\u003c\/p\u003e\n\u003cp\u003eThe final quotation should confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCosmetic condition\u003c\/li\u003e\n\u003cli\u003eFunctional testing\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance performed\u003c\/li\u003e\n\u003cli\u003eElectrical safety testing\u003c\/li\u003e\n\u003cli\u003eIncluded accessories\u003c\/li\u003e\n\u003cli\u003eIncluded blades and filters\u003c\/li\u003e\n\u003cli\u003eWarranty duration\u003c\/li\u003e\n\u003cli\u003eService coverage\u003c\/li\u003e\n\u003cli\u003eAvailability\u003c\/li\u003e\n\u003cli\u003eEstimated lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCleaning and Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe cast cutter and CastVac must be cleaned and maintained according to the current Stryker Instructions for Use.\u003c\/p\u003e\n\u003cp\u003eThe cast cutter must not be immersed, soaked, or sterilized. External surfaces should be cleaned and disinfected according to the manufacturer’s instructions. The CastVac is intended for dry materials only and must not be used to vacuum liquids or wet debris.\u003c\/p\u003e\n\u003cp\u003eThe filter cartridge, vacuum hose, power cords, blades, and system components should be inspected before use. Maintenance and repairs should be performed only by appropriately trained personnel.\u003c\/p\u003e\n\u003ch3\u003eImportant Safety Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor professional use by trained healthcare personnel\u003c\/li\u003e\n\u003cli\u003eRead the complete manufacturer Instructions for Use before operation\u003c\/li\u003e\n\u003cli\u003eSelect the correct blade for the cast material\u003c\/li\u003e\n\u003cli\u003eInspect the blade for wear before use\u003c\/li\u003e\n\u003cli\u003eDo not use a dull or damaged blade\u003c\/li\u003e\n\u003cli\u003eDo not use the CastVac for liquids or wet materials\u003c\/li\u003e\n\u003cli\u003eDo not immerse or sterilize the powered equipment\u003c\/li\u003e\n\u003cli\u003eConnect only compatible voltage configurations\u003c\/li\u003e\n\u003cli\u003eKeep electrical components away from moisture\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer’s duty-cycle requirements\u003c\/li\u003e\n\u003cli\u003eConfirm that the blade is properly secured before operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cp\u003eThis product is available through Request a Quote.\u003c\/p\u003e\n\u003cp\u003eBig Ben Medical Supplies will confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent availability\u003c\/li\u003e\n\u003cli\u003eFinal refurbished condition\u003c\/li\u003e\n\u003cli\u003eExact package contents\u003c\/li\u003e\n\u003cli\u003eShipping and handling cost\u003c\/li\u003e\n\u003cli\u003eDelivery requirements\u003c\/li\u003e\n\u003cli\u003eWarranty coverage\u003c\/li\u003e\n\u003cli\u003eService support\u003c\/li\u003e\n\u003cli\u003eEstimated lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eSupplier warranty and service coverage are available for the refurbished system. The warranty duration, covered components, exclusions, service process, and return requirements will be confirmed in the final quotation.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is included in this system?\u003c\/h3\u003e\n\u003cp\u003eThe vendor listing identifies this as a complete system containing the Stryker 940 Cast Cutter and Stryker 986 CastVac. Exact accessories, blades, filters, cords, and manuals must be confirmed in the final quotation.\u003c\/p\u003e\n\u003ch3\u003eIs this system new?\u003c\/h3\u003e\n\u003cp\u003eNo. This system is offered in refurbished condition.\u003c\/p\u003e\n\u003ch3\u003eWhat types of casts can the Stryker 940 remove?\u003c\/h3\u003e\n\u003cp\u003eThe Stryker 940 is designed to section and remove plaster and synthetic casts when used with the correct approved blade.\u003c\/p\u003e\n\u003ch3\u003eDoes the cast cutter have more than one speed?\u003c\/h3\u003e\n\u003cp\u003eYes. It has standard-speed, standby, and high-speed settings.\u003c\/p\u003e\n\u003ch3\u003eDoes the CastVac turn on automatically?\u003c\/h3\u003e\n\u003cp\u003eWhen properly connected and placed in standby mode, the CastVac can activate when the cast cutter is operated.\u003c\/p\u003e\n\u003ch3\u003eCan the Stryker 940 operate without the CastVac?\u003c\/h3\u003e\n\u003cp\u003eYes. The compatible 100–120V model can be connected to an appropriate facility power outlet or to the compatible CastVac.\u003c\/p\u003e\n\u003ch3\u003eDoes the package include cast-cutter blades?\u003c\/h3\u003e\n\u003cp\u003eBlade inclusion has not been confirmed. The final quotation must identify the quantity and type of blades provided.\u003c\/p\u003e\n\u003ch3\u003eCan the CastVac collect liquids?\u003c\/h3\u003e\n\u003cp\u003eNo. The CastVac is designed for dry cast debris only.\u003c\/p\u003e\n\u003ch3\u003eIs a warranty included?\u003c\/h3\u003e\n\u003cp\u003eThe supplier indicates that refurbished equipment is provided with service and warranty coverage. Exact terms must be confirmed in the final quotation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.stryker.com\/content\/dam\/stryker\/about\/our-locations\/apac\/ifus\/10-11-21\/instruments\/0940-001-025_Rev%20L.pdf\"\u003eStryker 940 Cast Cutter Instructions for Use\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.stryker.com\/content\/dam\/stryker\/about\/our-locations\/apac\/ifus\/10-11-21\/instruments\/0986-001-011_Rev%20R.pdf\"\u003eStryker 986 CastVac Instructions for Use\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Stryker-940-Cast-Cutter-Cast-Saw.pdf\"\u003eStryker 940 Product Specification Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Soma Tech International","offers":[{"title":"Default Title","offer_id":42343630078007,"sku":"BB-ST-CCV-0005","price":4449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/2167\/4039\/files\/images_c4e8dcac-49bc-48b3-bcb6-9fc1268d1914.jpg?v=1785426882","url":"https:\/\/bigbenmedical.com\/products\/stryker-940-cast-cutter-system-with-986-castvac-refurbished","provider":"Big Ben Medical Supplies","version":"1.0","type":"link"}