{"product_id":"welch-allyn-am-282-manual-screening-audiometer-with-case","title":"Welch Allyn AM 282 Manual Screening Audiometer with Case","description":"\u003cp\u003eThe Welch Allyn AM 282 Manual Audiometer is a compact, single-channel pure-tone audiometer designed for basic hearing screening in medical offices, occupational health programs, hospitals, clinics, and other suitable quiet testing environments.\u003c\/p\u003e\n\u003cp\u003eThe AM 282 provides 11 test frequencies from 125 Hz to 8,000 Hz, a broad hearing-level range, and steady, pulsed, and frequency-modulated tone options. Clearly labeled controls and an easy-to-read LCD display support efficient manual hearing assessments.\u003c\/p\u003e\n\u003cp\u003eThe lightweight tabletop design operates using AC power or five AA batteries and includes a soft carrying case for convenient transport between testing locations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-channel pure-tone air-conduction audiometer\u003c\/li\u003e\n\u003cli\u003e11 test frequencies from 125 Hz to 8,000 Hz\u003c\/li\u003e\n\u003cli\u003eAdjustable intensity in 5 dB steps\u003c\/li\u003e\n\u003cli\u003eAdditional 10 dB range-extension function000 Hz\u003c\/li\u003e\n\u003cli\u003eAdjustable intensity in 5 dB steps\u003c\/li\u003e\n\u003cli\u003eSteady, pulsed, and frequency-modulated test tones\u003c\/li\u003e\n\u003cli\u003eSeparate right-ear and left-ear test selection\u003c\/li\u003e\n\u003cli\u003eEasy-to-read LCD screen\u003c\/li\u003e\n\u003cli\u003eClearly labeled frequency and intensity controls\u003c\/li\u003e\n\u003cli\u003eDD45 external audiometry headset included\u003c\/li\u003e\n\u003cli\u003eCalibration storage for standard earphones\u003c\/li\u003e\n\u003cli\u003eCalibration storage for optional insert earphones\u003c\/li\u003e\n\u003cli\u003eOperates using AC power or five AA batteries\u003c\/li\u003e\n\u003cli\u003eMinimum battery operating time of approximately 10 hours\u003c\/li\u003e\n\u003cli\u003eLow-battery indicator\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight tabletop design\u003c\/li\u003e\n\u003cli\u003eSoft carrying case included\u003c\/li\u003e\n\u003cli\u003eSuitable for mobile and office-based hearing screening\u003c\/li\u003e\n\u003cli\u003eOne-year limited manufacturer warranty\u003c\/li\u003e\n\u003cli\u003ePrescription-use medical device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTest Frequencies\u003c\/h3\u003e\n\u003cp\u003eThe AM 282 provides the following discrete test frequencies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125 Hz\u003c\/li\u003e\n\u003cli\u003e250 Hz\u003c\/li\u003e\n\u003cli\u003e500 Hz\u003c\/li\u003e\n\u003cli\u003e750 Hz\u003c\/li\u003e\n\u003cli\u003e1,000 Hz\u003c\/li\u003e\n\u003cli\u003e1,500 Hz\u003c\/li\u003e\n\u003cli\u003e2,000 Hz\u003c\/li\u003e\n\u003cli\u003e3,000 Hz\u003c\/li\u003e\n\u003cli\u003e4,000 Hz\u003c\/li\u003e\n\u003cli\u003e6,000 Hz\u003c\/li\u003e\n\u003cli\u003e8,000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrequency accuracy is ±2%.\u003c\/p\u003e\n\u003ch3\u003eHearing-Level Ranges\u003c\/h3\u003e\n\u003cp\u003eStandard output ranges with the supplied external headset include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e125 Hz: −10 to 50 dB HL\u003c\/li\u003e\n\u003cli\u003e250 Hz: −10 to 70 dB HL\u003c\/li\u003e\n\u003cli\u003e500 to 4,000 Hz: −10 to 90 dB HL\u003c\/li\u003e\n\u003cli\u003e6,000 Hz: −10 to 85 dB HL\u003c\/li\u003e\n\u003cli\u003e8,000 Hz: −10 to 70 dB HL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe range-extension button can increase the maximum output at the selected frequency by an additional 10 dB.\u003c\/p\u003e\n\u003cp\u003eMaximum output levels may be lower when optional insert earphones are used.\u003c\/p\u003e\n\u003ch3\u003eTone Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous steady tone\u003c\/li\u003e\n\u003cli\u003ePulsed tone at approximately 2.5 pulses per second\u003c\/li\u003e\n\u003cli\u003eFrequency-modulated tone with ±5% modulation at 5 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Welch Allyn\u003c\/li\u003e\n\u003cli\u003eParent Company: Baxter\u003c\/li\u003e\n\u003cli\u003eProduct: AM 282 Manual Audiometer\u003c\/li\u003e\n\u003cli\u003eCatalog Number: 28200\u003c\/li\u003e\n\u003cli\u003eGTIN: 00732094082319\u003c\/li\u003e\n\u003cli\u003eInstrument Type: Single-channel screening audiometer\u003c\/li\u003e\n\u003cli\u003eTest Method: Pure-tone air-conduction audiometry\u003c\/li\u003e\n\u003cli\u003eFrequency Range: 125 Hz to 8,000 Hz\u003c\/li\u003e\n\u003cli\u003eFrequency Accuracy: ±2%\u003c\/li\u003e\n\u003cli\u003eIntensity Adjustment: 5 dB steps\u003c\/li\u003e\n\u003cli\u003eSignal-to-Noise Ratio: Greater than 70 dB\u003c\/li\u003e\n\u003cli\u003eTone Rise and Fall Time: 20–50 milliseconds\u003c\/li\u003e\n\u003cli\u003eDisplay: LCD\u003c\/li\u003e\n\u003cli\u003eIncluded Headset: DD45 external audiometry headset\u003c\/li\u003e\n\u003cli\u003eAC Adapter Input: Universal autoranging, 90–264V at 47–63Hz\u003c\/li\u003e\n\u003cli\u003eProduct Configuration: 100–240V, 50–60Hz AC, IEC Type-B plug\u003c\/li\u003e\n\u003cli\u003ePower Consumption: Approximately 1.5 watts\u003c\/li\u003e\n\u003cli\u003eBattery Requirement: Five AA batteries\u003c\/li\u003e\n\u003cli\u003eApproximate Battery Capacity: Minimum 10 hours\u003c\/li\u003e\n\u003cli\u003eDimensions: 12.59 W × 8.76 D × 3.18 H inches\u003c\/li\u003e\n\u003cli\u003eMetric Dimensions: 32 W × 22.3 D × 8.1 H cm\u003c\/li\u003e\n\u003cli\u003eInstrument Weight: Approximately 2.55 lb \/ 1.16 kg with batteries\u003c\/li\u003e\n\u003cli\u003eShipping Weight: Approximately 3.72 kg\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003cli\u003ePackaging: 1 each\u003c\/li\u003e\n\u003cli\u003eWarranty: One-year limited manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eRegulatory Status: Rx only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded Components\u003c\/h3\u003e\n\u003cp\u003eThe standard 28200 configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWelch Allyn AM 282 Manual Audiometer\u003c\/li\u003e\n\u003cli\u003eDD45 external audiometry headset\u003c\/li\u003e\n\u003cli\u003eThreshold audiometry reference card\u003c\/li\u003e\n\u003cli\u003eAudiogram forms, one pad of 50\u003c\/li\u003e\n\u003cli\u003eSoft carrying and storage case\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003ePower plug\u003c\/li\u003e\n\u003cli\u003eInstructions for Use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePackage contents should be confirmed before order completion.\u003c\/p\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003cp\u003eOptional accessories may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatient response hand switch\u003c\/li\u003e\n\u003cli\u003ePatient response patch cord\u003c\/li\u003e\n\u003cli\u003eAudiocups\u003c\/li\u003e\n\u003cli\u003eCompatible insert earphones\u003c\/li\u003e\n\u003cli\u003eReplacement audiogram forms\u003c\/li\u003e\n\u003cli\u003eReplacement headset\u003c\/li\u003e\n\u003cli\u003eReplacement power supply\u003c\/li\u003e\n\u003cli\u003eReplacement carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories are sold separately unless specifically included in the final quotation.\u003c\/p\u003e\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\u003cp\u003eThe Welch Allyn AM 282 may support hearing screening in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary care and family medicine offices\u003c\/li\u003e\n\u003cli\u003eOccupational health clinics\u003c\/li\u003e\n\u003cli\u003eENT and otolaryngology practices\u003c\/li\u003e\n\u003cli\u003eAudiology departments\u003c\/li\u003e\n\u003cli\u003eHospitals and outpatient clinics\u003c\/li\u003e\n\u003cli\u003eSchool and community hearing-screening programs\u003c\/li\u003e\n\u003cli\u003eEmployee health programs\u003c\/li\u003e\n\u003cli\u003eMobile medical services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe device should be used in a suitable quiet environment by an audiologist, ENT professional, hearing healthcare professional, or appropriately trained technician.\u003c\/p\u003e\n\u003ch3\u003eOperation and Testing Environment\u003c\/h3\u003e\n\u003cp\u003eExcessive background noise can affect hearing-screening results. Testing should be performed in a quiet environment that meets the facility’s clinical protocol and applicable hearing-screening requirements.\u003c\/p\u003e\n\u003cp\u003eThe earphones must be placed correctly, and obstructions such as hair, eyeglasses, earrings, or hearing aids should be removed from between the earphone cushion and the patient’s ear.\u003c\/p\u003e\n\u003ch3\u003eCalibration and Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe AM 282 is a calibrated medical instrument. The manufacturer recommends professional calibration annually or sooner when a performance concern is identified.\u003c\/p\u003e\n\u003cp\u003eThe audiometer, headset, cords, controls, and accessories should be inspected regularly. Calibration, service, and internal adjustments should be performed only by an authorized or appropriately qualified service technician.\u003c\/p\u003e\n\u003cp\u003eUse only compatible manufacturer-recommended accessories and power supplies.\u003c\/p\u003e\n\u003ch3\u003eCleaning\u003c\/h3\u003e\n\u003cp\u003eClean the device and reusable patient-contact components according to the current manufacturer Instructions for Use and the healthcare facility’s infection-control procedures.\u003c\/p\u003e\n\u003cp\u003eDo not allow fluids to enter the audiometer, electrical connectors, headset, or internal components. Do not operate the device when damaged, wet, improperly calibrated, or missing required components.\u003c\/p\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cp\u003eThis product is available through Request a Quote.\u003c\/p\u003e\n\u003cp\u003eBig Ben Medical Supplies will confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent product availability\u003c\/li\u003e\n\u003cli\u003eFinal selling price\u003c\/li\u003e\n\u003cli\u003ePackage contents\u003c\/li\u003e\n\u003cli\u003eShipping and handling cost\u003c\/li\u003e\n\u003cli\u003eDelivery requirements\u003c\/li\u003e\n\u003cli\u003eWarranty coverage\u003c\/li\u003e\n\u003cli\u003eCalibration status\u003c\/li\u003e\n\u003cli\u003eEstimated lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe Welch Allyn AM 282 includes a one-year limited manufacturer warranty covering defects in materials and workmanship under the manufacturer’s stated terms.\u003c\/p\u003e\n\u003cp\u003eFinal warranty coverage, transportation costs, exclusions, registration requirements, and service procedures will be confirmed before order completion.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Welch Allyn AM 282 used for?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for basic pure-tone air-conduction hearing screening in clinical, occupational, and other suitable quiet testing environments.\u003c\/p\u003e\n\u003ch3\u003eWhat frequencies can it test?\u003c\/h3\u003e\n\u003cp\u003eThe device provides 11 frequencies from 125 Hz to 8,000 Hz.\u003c\/p\u003e\n\u003ch3\u003eDoes the AM 282 include a headset?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard 28200 package includes a DD45 external audiometry headset.\u003c\/p\u003e\n\u003ch3\u003eDoes it operate on batteries?\u003c\/h3\u003e\n\u003cp\u003eYes. It can operate using five AA batteries and provides a minimum operating time of approximately 10 hours under the manufacturer’s stated conditions.\u003c\/p\u003e\n\u003ch3\u003eDoes it include an AC power supply?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard configuration includes the power supply and power plug.\u003c\/p\u003e\n\u003ch3\u003eIs a carrying case included?\u003c\/h3\u003e\n\u003cp\u003eYes. A soft carrying and storage case is included.\u003c\/p\u003e\n\u003ch3\u003eDoes it include audiogram forms?\u003c\/h3\u003e\n\u003cp\u003eYes. The standard package includes one pad containing 50 audiogram forms.\u003c\/p\u003e\n\u003ch3\u003eDoes it include a patient response button?\u003c\/h3\u003e\n\u003cp\u003eThe patient response hand switch is listed as an optional accessory and is not included unless specifically stated in the final quotation.\u003c\/p\u003e\n\u003ch3\u003eIs this a diagnostic audiometer?\u003c\/h3\u003e\n\u003cp\u003eThe AM 282 is a screening audiometer intended for basic audiometric assessments. It should not be represented as a complete clinical diagnostic audiology system.\u003c\/p\u003e\n\u003ch3\u003eHow often should the audiometer be calibrated?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer recommends annual calibration or earlier when a performance issue is suspected.\u003c\/p\u003e\n\u003ch3\u003eWho should operate the device?\u003c\/h3\u003e\n\u003cp\u003eIt is intended for use by audiologists, ENT professionals, hearing healthcare professionals, or appropriately trained technicians.\u003c\/p\u003e\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\u003cp\u003eOfficial Baxter\/Welch Allyn Product Page\u003cbr\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.hillrom.com\/en\/products\/am-282-manual-audiometer\/?utm_source=chatgpt.com\"\u003ehttps:\/\/www.hillrom.com\/en\/products\/am-282-manual-audiometer\/\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eOfficial AM 282 Instructions for Use — PDF\u003cbr\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.hillrom.ca\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80016\/80016447LITPDF.pdf\"\u003ehttps:\/\/www.hillrom.ca\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80016\/80016447LITPDF.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eOfficial AM 282 Product Sell Sheet and Specifications — PDF\u003cbr\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.hillrom.ca\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80011\/80011946LITPDF.pdf\"\u003ehttps:\/\/www.hillrom.ca\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80011\/80011946LITPDF.pdf\u003c\/a\u003e\u003c\/p\u003e","brand":"\" Baxter\/Welch Allyn \"","offers":[{"title":"Default Title","offer_id":42343643381815,"sku":"BB-WA28200","price":2400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/2167\/4039\/files\/images_3d1969ba-d47b-4f83-95cd-442ff8ca8cef.jpg?v=1785428107","url":"https:\/\/bigbenmedical.com\/products\/welch-allyn-am-282-manual-screening-audiometer-with-case","provider":"Big Ben Medical Supplies","version":"1.0","type":"link"}