{"product_id":"welch-allyn-h12-12-lead-48-hour-digital-holter-recorder","title":"Welch Allyn H12+ 12-Lead 48-Hour Digital Holter Recorder","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWelch Allyn H12+ Digital Holter Recorder\u003c\/strong\u003e is a professional \u003cstrong\u003e12-lead ambulatory ECG recorder\u003c\/strong\u003e designed for extended cardiac monitoring in cardiology practices, diagnostic centers, hospitals, and other clinical environments. The selected configuration provides up to \u003cstrong\u003e48 hours of recording\u003c\/strong\u003e while simultaneously acquiring the standard 12 ECG leads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCompact and lightweight, the H12+ stores recorded ECG information on a removable \u003cstrong\u003eSecure Digital (SD) memory card\u003c\/strong\u003e for transfer into a compatible Holter analysis workflow. The recorder is compatible with the \u003cstrong\u003eWelch Allyn HScribe Holter Analysis System\u003c\/strong\u003e, which incorporates VERITAS signal-processing and analysis capabilities. \u003cstrong\u003eHScribe software\/system is separate and should not be considered included with this recorder unless specifically quoted.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe H12+ supports lead-quality checking, ECG display, pacemaker detection, and standard 12-lead ambulatory recording. Baxter's documentation specifies simultaneous acquisition of leads \u003cstrong\u003eI, II, III, aVR, aVL, aVF, and V1–V6\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSelected Configuration Includes\u003c\/h3\u003e\n\u003cp\u003eBased on the selected \u003cstrong\u003eH12PLUS-MPA-XXXXX\u003c\/strong\u003e IMCO configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eH12+ 12-lead digital Holter recorder\u003c\/li\u003e\n\u003cli\u003e48-hour recording configuration\u003c\/li\u003e\n\u003cli\u003eSecure Digital (SD) card\u003c\/li\u003e\n\u003cli\u003eCarry case\u003c\/li\u003e\n\u003cli\u003eHookup kit\u003c\/li\u003e\n\u003cli\u003eAHA 10-wire patient cable\u003c\/li\u003e\n\u003cli\u003e12-lead LeadForm patient cable, approximately 38 in. \/ 97 cm\u003c\/li\u003e\n\u003cli\u003eSnap-end connections\u003c\/li\u003e\n\u003cli\u003eMultiple-language \/ CD manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e12-lead digital Holter recording\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e48-hour ambulatory ECG recording\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSimultaneous acquisition of all 12 standard ECG leads\u003c\/li\u003e\n\u003cli\u003eECG display for signal review\u003c\/li\u003e\n\u003cli\u003eLead-quality check\u003c\/li\u003e\n\u003cli\u003ePacemaker detection capability\u003c\/li\u003e\n\u003cli\u003eSD memory-card storage\u003c\/li\u003e\n\u003cli\u003eCompact portable design\u003c\/li\u003e\n\u003cli\u003eApproximately \u003cstrong\u003e4 oz \/ 125 g without battery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePowered by \u003cstrong\u003eone AA alkaline battery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eStandard recording frequency response of approximately \u003cstrong\u003e0.05–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with Welch Allyn HScribe Holter Analysis System \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCardiology practices\u003c\/li\u003e\n\u003cli\u003eArrhythmia evaluation\u003c\/li\u003e\n\u003cli\u003eExtended ambulatory ECG monitoring\u003c\/li\u003e\n\u003cli\u003eEvaluation of intermittent cardiac rhythm abnormalities\u003c\/li\u003e\n\u003cli\u003eInternal medicine\u003c\/li\u003e\n\u003cli\u003eOutpatient cardiac diagnostic services\u003c\/li\u003e\n\u003cli\u003eHospitals and diagnostic centers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe recorder captures physiological ECG data for later review by appropriately trained clinicians; Baxter's documentation notes that recorder data is intended for use with a properly equipped analysis system and clinician review. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant System Note\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe H12+ is the recording device, not a complete standalone Holter analysis workstation.\u003c\/strong\u003e For full data analysis and reporting capability, the recorder is designed to operate as part of a compatible analysis workflow such as \u003cstrong\u003eHScribe\u003c\/strong\u003e. This distinction should remain clear in the Shopify listing so customers do not assume analysis software is included with the recorder.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eFAQ\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow long can the H12+ record ECG data?\u003c\/strong\u003e\u003cbr\u003eThe selected configuration supports \u003cstrong\u003e48-hour recording\u003c\/strong\u003e. Baxter's manual notes that the 48-hour recorder automatically transitions into the second 24-hour period. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many ECG leads does the H12+ record?\u003c\/strong\u003e\u003cbr\u003eIt is a \u003cstrong\u003e12-lead Holter recorder\u003c\/strong\u003e, simultaneously acquiring the standard 12 ECG leads. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the recorder include analysis software?\u003c\/strong\u003e\u003cbr\u003eDo not assume so. The H12+ is compatible with the \u003cstrong\u003eHScribe Holter Analysis System\u003c\/strong\u003e, which is a separate analysis solution unless specifically included in a quotation or package. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is recorded data transferred?\u003c\/strong\u003e\u003cbr\u003eThe H12+ stores recordings on removable SD media, which can be imported into the compatible analysis system. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat battery does the H12+ use?\u003c\/strong\u003e\u003cbr\u003eThe manufacturer specifies \u003cstrong\u003eone AA alkaline battery\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the H12+ portable?\u003c\/strong\u003e\u003cbr\u003eYes. The recorder weighs approximately \u003cstrong\u003e4 oz \/ 125 g without the battery\u003c\/strong\u003e and is designed for ambulatory monitoring. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eManufacturer Documents \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eH12+ Digital Holter Recorder — User Manual (PDF)\u003c\/strong\u003e\u003cbr\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.hillrom.co.uk\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/9515-\/9515-160-50-ENGLITPDF.pdf\"\u003ehttps:\/\/www.hillrom.co.uk\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/9515-\/9515-160-50-ENGLITPDF.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eH12+ 12-Lead Holter Electrode Placement — Quick Reference Guide (PDF)\u003c\/strong\u003e\u003cbr\u003e\u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.hillrom.co.uk\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80025\/80025607LITPDF.pdf\"\u003ehttps:\/\/www.hillrom.co.uk\/content\/dam\/hillrom-aem\/us\/en\/sap-documents\/LIT\/80025\/80025607LITPDF.pdf\u003c\/a\u003e\u003c\/p\u003e","brand":"\" Baxter\/Welch Allyn \"","offers":[{"title":"Default Title","offer_id":42378950377527,"sku":"BB-WA-H12PLUS","price":3699.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/2167\/4039\/files\/images_29801bc2-61e9-4f5d-bb43-106fa4de9083.jpg?v=1786464630","url":"https:\/\/bigbenmedical.com\/products\/welch-allyn-h12-12-lead-48-hour-digital-holter-recorder","provider":"Big Ben Medical Supplies","version":"1.0","type":"link"}