Integra Miltex CryoSolutions 33510 Cryosurgical System Complete Set
Integra Miltex CryoSolutions 33510 Cryosurgical System Complete Set
SKU:BB-ST3510
Default Title
Request a quotation to confirm product availability, final shipping cost, and delivery requirements before ordering.
Default Title

Portable cryosurgical treatment using liquefied nitrous oxide
The Integra Miltex CryoSolutions 33510 Complete Set is a compact, self-contained cryosurgical system designed to deliver liquefied nitrous oxide directly to a targeted treatment site.
The trigger-controlled applicator allows qualified clinicians to start and stop cryogen flow while positioning the dispensing tip directly against the selected tissue. The system provides cold performance down to approximately -89°C / -128°F for the destruction of unwanted tissue during cryosurgical procedures.
CryoSolutions is suitable for trained medical professionals performing approved cryosurgical procedures in dermatology, podiatry, gynecology, physician offices, outpatient clinics, and other procedure-room environments.
Complete portable system
The 33510 set includes the CryoSolutions applicator, standard 1 mm dispensing tip, tip protector, one 23.5 g medical-grade nitrous oxide cartridge, installation and removal pin, user instructions, and protective carrying case.
The portable configuration does not require electrical power or a separate external gas cylinder, allowing the system to be stored and transported easily between compatible procedure rooms.
Trigger-controlled cryogen delivery
The applicator incorporates a trigger that opens and closes the internal valve to control the flow of liquefied nitrous oxide.
The clinician positions the selected dispensing tip against the treatment site and activates the trigger to deliver cryogen through the tip. Treatment duration must be selected by the qualified clinician according to the type, size, depth, and location of the tissue being treated.
Standard 1 mm contact tip
The complete set includes a standard 1 mm borosilicate glass dispensing tip enclosed in a gold-plated metal housing.
The contact-style tip is placed perpendicular to the treatment surface without additional pressure. Other compatible tip sizes and configurations are available separately for different clinical applications.
Medical-grade nitrous oxide cartridge
The system includes one threaded cartridge containing approximately 23.5 g of medical-grade nitrous oxide.
The cartridge operates at a content pressure of approximately 50 bar and connects directly to the CryoSolutions control mechanism. Only compatible cartridges specified for the CryoSolutions system should be used.
Durable reusable control mechanism
The CryoSolutions control mechanism incorporates gold-plated brass and stainless-steel components, a safety filter, internal seals, and a trigger-operated dosing valve.
The reusable applicator should be inspected before every procedure. The control mechanism must not be steam sterilized or immersed.
Reusable sterilizable dispensing tips
The dispensing tip should be removed from the applicator before cleaning and sterilization.
Glass tips that contact blood, mucous membranes, or infected tissue may be steam sterilized at 134°C / 273°F for nine minutes according to the manufacturer’s instructions. Dry-heat sterilization is not recommended.
Only the removable glass dispensing tips should be steam sterilized. The control mechanism must not be placed in a steam sterilizer.
Protective storage case
The included carrying case protects the applicator, dispensing tip, cartridge components, and metal pin during storage and transportation.
The tip protector should be installed whenever the system is not in use. The device and cartridges should be stored in a dry location protected from sunlight at temperatures between -5°C and 50°C / 23°F and 122°F.
Key Features
- Portable cryosurgical treatment system
- Uses liquefied medical-grade nitrous oxide
- Cold performance down to approximately -89°C / -128°F
- Trigger-controlled cryogen delivery
- Reusable control mechanism
- Standard 1 mm contact tip included
- Borosilicate glass dispensing tip
- Gold-plated brass and stainless-steel components
- One 23.5 g nitrous oxide cartridge included
- Approximately 50-bar cartridge pressure
- No electrical connection required
- Self-contained handheld design
- Interchangeable dispensing tips
- Reusable steam-sterilizable glass tips
- Protective tip cap
- Protective carrying case
- One-year manufacturer limited warranty excluding cartridges
- Restricted to use by or on the order of a licensed practitioner
Common Applications
- Dermatology cryosurgical procedures
- Podiatry cryosurgical procedures
- Gynecology procedures with a compatible tip
- Physician-office procedures
- Outpatient procedure rooms
- Specialty medical practices
- Targeted destruction of unwanted tissue
- Treatment of clinically selected superficial lesions
- Minor office-based cryosurgery
Suitability, treatment duration, technique, and tip selection must be determined by a qualified clinician according to the official instructions for use.
Technical Specifications
Manufacturer: Integra LifeSciences Production Corporation
Brand: Integra Miltex
Product family: CryoSolutions
Model: 33510
Product type: Mechanical cryosurgical system
Cryogen: Medical-grade nitrous oxide
Refrigerating method: Open system
Maximum cold performance: Approximately -89°C / -128°F
Cartridge capacity: 23.5 g N₂O
Cartridge content pressure: Approximately 50 bar
Control mechanism materials: Gold-plated brass and stainless steel
Tip material: Borosilicate glass enclosed in gold-plated metal
Included tip width: 1 mm
Cryogen control: Trigger-operated valve
Electrical power required: No
Tip sterilization method: Steam sterilization
Recommended tip sterilization cycle: 134°C / 273°F for nine minutes
Control-mechanism sterilization: Do not steam sterilize
Storage temperature: -5°C to 50°C / 23°F to 122°F
Warranty: One-year manufacturer limited warranty for CryoSolutions products excluding cartridges
Prescription status: Federal law restricts this device to sale by or on the order of a licensed practitioner
What Is Included
- Integra Miltex CryoSolutions applicator
- Standard 1 mm dispensing tip
- Tip protector
- One 23.5 g medical-grade nitrous oxide cartridge
- Metal cartridge installation and removal pin
- User instructions
- Protective plastic carrying case
Compatible Accessories
- CryoSolutions 1 mm standard dispensing tip
- CryoSolutions 2 mm dermatology dispensing tip
- CryoSolutions 3 mm dermatology dispensing tip
- CryoSolutions 4 mm dermatology dispensing tip
- CryoSolutions gynecology dispensing tip
- Replacement medical-grade N₂O cartridges
- Replacement protective carrying case
- Replacement metal cartridge pin
Accessories and replacement cartridges are sold separately.
Frequently Asked Questions
What is the CryoSolutions 33510 system used for?
The CryoSolutions system is indicated for the destruction of unwanted tissue during cryosurgical procedures through the application of extreme cold.
What cryogen does the system use?
It uses compatible threaded cartridges containing medical-grade nitrous oxide.
How cold does the system become?
The manufacturer lists cold performance down to approximately -89°C / -128°F.
Does the system require electrical power?
No. CryoSolutions is a self-contained mechanical system powered by a nitrous oxide cartridge.
What dispensing tip is included?
The complete set includes a standard 1 mm contact-style glass dispensing tip and tip protector.
Are other tip sizes available?
Yes. Compatible 2 mm, 3 mm, and 4 mm dermatology tips and a longer gynecology tip are available separately.
How is the cryogen flow controlled?
The clinician presses the trigger to open the valve and releases it to stop the flow of liquefied nitrous oxide.
Is a nitrous oxide cartridge included?
Yes. One compatible 23.5 g medical-grade N₂O cartridge is included.
Can standard commercial nitrous oxide cartridges be used?
No. Only cartridges specified as compatible with the CryoSolutions system should be used.
Can the dispensing tips be sterilized?
Yes. The removable glass tips may be steam sterilized at 134°C / 273°F for nine minutes according to the manufacturer’s instructions.
Can the entire applicator be autoclaved?
No. Only the removable dispensing tips may be steam sterilized. The control mechanism must not be placed in a steam sterilizer.
Does the system include a carrying case?
Yes. A protective plastic carrying case is included.
What warranty is provided?
The manufacturer provides a one-year limited warranty covering defects in materials and workmanship under normal use. The nitrous oxide cartridge is excluded from the warranty.
Who may use the CryoSolutions system?
The system is intended for qualified medical professionals trained in cryosurgical procedures. Federal law restricts the device to sale by or on the order of a licensed practitioner.