The Integra Miltex Schiotz Tonometer is a reusable manual ophthalmic instrument designed to measure intraocular pressure using the Schiotz indentation tonometry method. It is suitable for ophthalmology practices, eye clinics, hospitals, medical offices, and other professional clinical environments.

Model 18-132 is supplied with three measurement weights, a stainless-steel plunger, stainless-steel footplate, stainless-steel test block, and a fitted storage case. Its engraved, inclined scale supports convenient reading from above during clinical use.

Key Features

  • Manual indentation tonometer for intraocular pressure measurement
  • Original Schiotz design
  • Includes three measurement weights
  • 5.5 g weight
  • 7.5 g weight
  • 10 g weight
  • Stainless-steel plunger
  • Stainless-steel footplate
  • Stainless-steel test block
  • Etched scale markings for clear reading
  • Inclined scale can be read from above
  • Reusable and autoclavable construction
  • Supplied in a fitted storage case
  • No batteries or electrical power required
  • Compact design for clinical use and storage

Product Specifications

  • Manufacturer: Integra LifeSciences
  • Brand: Integra Miltex
  • Product: Schiotz Tonometer
  • Model: Original Model
  • Manufacturer Item Number: 18-132
  • Product Type: Manual ophthalmic tonometer
  • Measurement Method: Indentation tonometry
  • Included Weights: 5.5 g, 7.5 g, and 10 g
  • Plunger Material: Stainless steel
  • Footplate Material: Stainless steel
  • Test Block Material: Stainless steel
  • Power Material: Stainless steel
  • Test Block Material: Stainless steel
  • Power Requirement: None
  • Packaging: 1 each
  • Condition: New
  • UDI-DI: 10381780159544
  • FDA Device Category: Manual ophthalmic tonometer

Intended Use

The Integra Miltex Schiotz Tonometer is intended for manual measurement of intraocular pressure by trained healthcare professionals. It may be used during ophthalmic examinations and clinical assessment of patients who require intraocular pressure evaluation.

This device is not a digital or non-contact tonometer. Results must be interpreted by a qualified healthcare professional according to the applicable clinical protocol.

Included Components

  • Schiotz manual tonometer
  • 5.5 g measurement weight
  • 7.5 g measurement weight
  • 10 g measurement weight
  • Stainless-steel plunger
  • Stainless-steel footplate
  • Stainless-steel test block
  • Fitted storage case

Cleaning and Reprocessing

The tonometer is reusable and must be properly cleaned, disinfected, inspected, and sterilized according to the current manufacturer instructions and the healthcare facility’s infection-control procedures.

Review the latest Integra Instructions for Use before using or reprocessing the instrument. Do not use the device if it is damaged, improperly calibrated, contaminated, or missing required components.

Important Information

  • For professional use only
  • Use only by appropriately trained healthcare personnel
  • Follow the current manufacturer Instructions for Use
  • Verify the instrument before every procedure
  • Use the test block to check instrument operation
  • Follow applicable infection-control and sterilization procedures
  • Product appearance and packaging may vary
  • Confirm current availability and package contents before ordering

Product Documentation

Instructions for Use / Operator Manual
Search for reference number 18-132 in the official Integra document portal:
https://labeling.integralife.com/eifu/pages/eifu-home

FDA AccessGUDID Device Record
Search for catalog number 18-132 or UDI-DI 10381780159544:
https://accessgudid.nlm.nih.gov/devices/search?query=18-132

Product Specification Reference
https://shop.cardinalhealth.ca/chc/schiotz-tonometer-original-model

Additional Product Details
https://shop.benco.com/Product/4083-243/schiotz-tonometer-original-model

Manufacturer Warranty, Terms and Conditions
https://www.integralife.com/warranty

Frequently Asked Questions

What does the Integra Miltex Schiotz Tonometer measure?
It is used by trained healthcare professionals to manually measure intraocular pressure using indentation tonometry.

Which weights are included?
The 18-132 configuration includes 5.5 g, 7.5 g, and 10 g measurement weights.

Does the tonometer require batteries?
No. It is a fully manual instrument and does not require batteries or electrical power.

Is this a digital tonometer?
No. This is a manual Schiotz indentation tonometer.

Is the instrument reusable?
Yes. It is reusable and must be cleaned, inspected, disinfected, and sterilized according to the current manufacturer instructions.

Does it include a storage case?
Yes. The instrument is supplied in a fitted case with its weights and test block.

Who should use this device?
The device is intended for use by trained and qualified healthcare professionals.