Philips PageWriter TC70 Diagnostic ECG Cardiograph (Refurbished)
Philips PageWriter TC70 Diagnostic ECG Cardiograph (Refurbished)
SKU:BB-PH-EKG-0003
Default Title
Request a quotation to confirm product availability, final shipping cost, and delivery requirements before ordering.
Default Title

The Philips PageWriter TC70 Cardiograph is an advanced diagnostic ECG system designed for high-volume cardiology, hospital, and enterprise clinical environments where comprehensive ECG analysis and connected workflow are essential.
The TC70 combines a large 15-inch touchscreen with Philips' DXL 18-Lead ECG Algorithm, allowing simultaneous acquisition and interpretation of up to 18 leads. The system supports standard 12-lead ECG testing as well as extended right-chest and posterior leads for more comprehensive cardiac assessment.
Designed to streamline ECG workflow from acquisition through reporting, the PageWriter TC70 can acquire, analyze, print, store, retrieve, and transmit ECG studies. Its integrated clinical tools include LeadCheck for detecting possible lead reversals, signal-quality indicators, Critical Values, extended-lead interpretation, and advanced STEMI diagnostic aids.
The PageWriter TC70 also supports enterprise connectivity using standard formats including PDF, Philips XML, DICOM 12-Lead ECG, DICOM General ECG, and DICOM Encapsulated PDF, making it well suited for integration with compatible ECG management, PACS, and hospital information workflows.
Key Features
- Diagnostic resting ECG cardiograph
- Simultaneous acquisition of up to 18 leads
- 15-inch TFT touchscreen
- Philips DXL 18-Lead ECG Algorithm
- More than 600 interpretive statements
- Integrated pediatric ECG analysis
- Standard 12-lead plus extended right-chest and posterior leads
- LeadCheck lead-reversal detection
- Color-coded signal-quality indicators
- Critical Values clinical alerts
- Advanced STEMI diagnostic aids
- ST Maps
- Full Disclosure with up to 20 minutes of ECG history
- Up to 15 cardiac events can be marked for later review
- Integrated high-resolution thermal printer
- Internal storage for up to 200 ECGs
- Wired LAN connectivity
- Optional wireless network connectivity
- PDF, Philips XML, and DICOM report formats
- Orders/worklist capability with compatible enterprise systems
- AC and battery-powered operation
ECG and Clinical Capabilities
Simultaneous Lead Acquisition: Up to 18 leads
Standard Diagnostic Leads:
I, II, III, aVR, aVL, aVF, V1–V6
Extended Diagnostic Leads:
V3R, V4R, V5R, V7, V8, V9
Interpretation: Philips DXL 18-Lead ECG Algorithm
Interpretive Statements: More than 600
Pediatric Analysis: Integrated
Rhythm Strips: Up to 18 configurable leads
Full Disclosure: Up to 20 minutes of ECG history with the ability to generate a complete ECG report from a selected 10-second period
Event Marking: Up to 15 independent cardiac events
Internal ECG Storage: Up to 200 ECGs
Report Formats: PDF, Philips XML, DICOM General ECG, DICOM 12-Lead ECG, and DICOM Encapsulated PDF
Advanced Clinical Decision Support
The PageWriter TC70 provides several tools designed to support efficient ECG review:
- Graphical ST Maps
- Right-heart interpretive statements
- Posterior myocardial infarction statements
- STEMI-CA culprit-artery criteria
- Critical Values alerts
- LeadCheck lead-placement verification
- Age- and gender-specific interpretation criteria
- Selectable explanations for interpretive statements
Display
Display Type: TFT touchscreen
Display Size: 15 in diagonal
Resolution: 1024 × 768 XGA
Colors: 64K
Screen Adjustment: Approximately 137° tilt
Printer
- Integrated high-resolution digital thermal printer
- Supports letter-size and A4 Z-fold thermal paper
- 200 dpi voltage-axis resolution
- 500 dpi time-axis resolution at 25 mm/sec
Connectivity
Depending on configuration and connected hospital infrastructure, the PageWriter TC70 supports:
- Ethernet LAN
- Wi-Fi
- Philips XML
- DICOM 12-Lead ECG
- DICOM General ECG
- DICOM Encapsulated PDF
- DICOM Modality Worklist
- HL7 workflows through compatible Philips enterprise solutions
- Orders and worklist retrieval
- Previous-ECG retrieval with compatible ECG management systems
Specific software licenses, wireless hardware, DICOM options, and enterprise interfaces should be confirmed for the individual system configuration before ordering.
Clinical Applications
Suitable for:
- Cardiology departments
- Diagnostic cardiology centers
- Hospitals
- Emergency departments
- Specialty outpatient centers
- High-volume ECG services
- Multi-site healthcare organizations
- Enterprise ECG environments
- Adult and pediatric ECG assessment
Manufacturer Documentation
Philips PageWriter TC70 Product Brochure & Technical Specifications — Official PDF
https://www.documents.philips.com/assets/20181016/1d36b62c142641129f0aa97b012db296.pdf
Shipping Information
Product Weight: 28 lb
Product Dimensions: 15.94 × 12.99 × 5.31 in
Shipping Weight: Vendor confirmation required
Shipping Carton Dimensions: Vendor confirmation required
The published dimensions and weight refer to the equipment configuration rather than the shipping carton. Actual packaged weight and carton dimensions should therefore be confirmed before using carrier-calculated shipping.
FAQ
Is the PageWriter TC70 a 12-lead ECG?
Yes. It performs standard diagnostic 12-lead ECG testing and can expand acquisition and interpretation to as many as 18 leads.
What is the Philips DXL ECG Algorithm?
The DXL algorithm provides ECG measurement and interpretation across up to 18 leads and includes more than 600 interpretive statements, pediatric analysis, and advanced STEMI-related tools.
Does the TC70 support DICOM?
Yes. Philips supports DICOM 12-Lead ECG, General ECG, Encapsulated PDF, and DICOM Modality Worklist workflows. Exact installed options should be confirmed for the specific system.
Does it support pediatric ECG analysis?
Yes. Pediatric ECG analysis is integrated into the DXL interpretation platform.
What is Full Disclosure?
The TC70 can retain up to 20 minutes of ECG history across up to 18 leads, allowing a clinician to review earlier ECG activity and generate a report from a selected 10-second segment.
Can it operate on battery power?
Yes. The TC70 uses two lithium-ion battery modules and can operate independently of AC power.