Welch Allyn MicroTymp 4 Portable Tympanometer System with Printer

Welch Allyn MicroTymp 4 Portable Tympanometer System with Printer

SKU:BB-WA-93700

Login view prices
Shipping calculated at checkout.
Default Title

Request a quotation to confirm product availability, final shipping cost, and delivery requirements before ordering.

Default Title
View full details

Portable middle-ear assessment with printed and digital results

The Welch Allyn MicroTymp 4 is a handheld portable tympanometer designed to provide objective analysis of tympanic membrane mobility and middle-ear function.

The system supports tympanometry and ipsilateral acoustic reflex testing, helping qualified healthcare professionals document and evaluate possible middle-ear disorders alongside otoscopic examination and other clinically appropriate assessments. It is designed for use in hospitals, clinics, physician offices, hearing-care practices, and other healthcare environments with a suitable quiet testing area.

The 93700 configuration includes the MicroTymp 4 handheld instrument, charging cradle, ear-tip starter kit, four-volume test cavity, probe-tip cleaning kit, data cables, TympView software, and an MPT-II printer kit for immediate printed reports.

Fast automatic testing

The MicroTymp 4 automatically begins recording a tympanogram once an adequate seal is achieved in the ear canal.

Each ear can be tested in as little as approximately three seconds. Four-button navigation allows the clinician to select the left ear, right ear, or both ears and move through the testing and result-review workflow. The current product information identifies the system for testing patients six months of age and older.

Tympanometry measurements

The MicroTymp 4 uses a 226 Hz probe tone to assess middle-ear function over a pressure range from approximately +200 daPa to -400 daPa.

The system measures and displays:

  • Tympanic peak pressure
  • Admittance at peak
  • Ear canal volume
  • Tympanometric gradient
  • Tympanogram curve

The instrument automatically measures ear canal volume, locates the tympanic admittance peak, and calculates the corresponding pressure and gradient.

Ipsilateral acoustic reflex testing

The MicroTymp 4 also supports automatic ipsilateral acoustic reflex measurement.

Reflex testing can be performed at:

  • 500 Hz
  • 1,000 Hz
  • 2,000 Hz
  • 4,000 Hz

The system provides configurable reflex settings, automatic detection, pass-or-fail results at each tested level, maximum reflex amplitude, and the pressure at which the reflex was measured.

Integrated printer system

The included MPT-II printer kit allows clinicians to produce printed tympanometry and acoustic reflex results at the point of care.

Printed reports can support chart documentation, referral communication, patient education, and clinical review. Thermal-paper results should be copied or entered into the permanent patient record because thermal printouts may fade when exposed to heat or light.

TympView software and USB data transfer

The included TympView software allows compatible test results to be transferred to a computer using the supplied USB data cable.

Results can be viewed on a computer, saved as PDF files, and printed for documentation or referral support. The system can store up to 32 test records internally before records must be printed, transferred, or deleted.

Rechargeable handheld operation

The handheld tympanometer uses an internal rechargeable nickel-metal hydride battery pack.

A fully charged device can capture up to approximately 100 recordings. The supplied charging cradle connects to 100–240 VAC power at 50/60 Hz and provides visual indicators for mains power and battery charging status. The internal battery is not intended to be replaced by the user.

Pediatric-friendly workflow

Fast automatic testing, multiple disposable ear-tip sizes, and simple four-button navigation make the MicroTymp 4 suitable for pediatric and adult middle-ear assessment.

The patient should remain still and avoid talking, swallowing, or moving while the probe is positioned. A new single-use ear tip must be selected for each tested ear and fitted securely without blocking the probe openings.

Daily checks and routine maintenance

The system includes a four-volume test cavity for daily functional checks.

The manufacturer recommends performing the specified checks before the instrument’s first use each day and whenever results appear inconsistent. The probe tip should be inspected and cleaned according to the official cleaning instructions, and the instrument should be returned for annual calibration.

Key Features

  • Portable handheld tympanometer
  • Tympanometry testing
  • Ipsilateral acoustic reflex testing
  • Testing in as little as approximately three seconds per ear
  • Automatic testing after an adequate ear-canal seal is obtained
  • Four-button navigation
  • Left-ear, right-ear, or bilateral testing
  • Designed for patients six months of age and older
  • 226 Hz probe tone
  • Pressure range from approximately +200 to -400 daPa
  • Ear canal volume measurement
  • Tympanic peak pressure measurement
  • Peak admittance measurement
  • Tympanometric gradient measurement
  • Reflex testing at 500 Hz, 1,000 Hz, 2,000 Hz, and 4,000 Hz
  • Automatic reflex detection
  • Up to 32 internally stored test records
  • Up to approximately 100 recordings per full charge
  • Rechargeable handheld operation
  • Charging cradle included
  • MPT-II printer kit included
  • TympView software included
  • USB data transfer
  • PDF result-saving capability
  • Four-volume test cavity included
  • Ear-tip starter kit included
  • One-year manufacturer limited warranty

Common Applications

  • Objective middle-ear assessment
  • Tympanometry
  • Ipsilateral acoustic reflex testing
  • Pediatric hearing and ear assessment
  • Adult hearing and ear assessment
  • Supporting otoscopic findings
  • Evaluation of patients reporting hearing concerns
  • Physician-office ENT assessment
  • Pediatric clinic assessment
  • Audiology and hearing-care practices
  • Urgent-care ear assessment
  • Primary-care practices
  • Referral documentation

The MicroTymp 4 should be used by qualified healthcare professionals in conjunction with otoscopy and other clinically appropriate testing.

Technical Specifications

Manufacturer: Welch Allyn

Product Family: MicroTymp 4

Model: 93700

Product Type: Handheld portable tympanometer system with printer

Instrument Classification: Meatus-compensated Type 2 tympanometer

Testing Modes: Tympanometry and ipsilateral acoustic reflex testing

Probe Tone: 226 Hz ±2%

Probe Tone Level: 85 dB SPL ±2 dB over a 0.2–5 mL range

Pressure Range: +200 daPa to -400 daPa

Pressure Accuracy: ±10 daPa or ±10%, whichever is greater

Ear Canal Volume Range: 0.2–5 mL

Ear Canal Volume Accuracy: ±0.1 mL or ±5%, whichever is greater

Measured Tympanometry Parameters:

  • Tympanic peak pressure
  • Admittance at peak
  • Ear canal volume
  • Gradient

Acoustic Reflex Mode: Ipsilateral

Acoustic Reflex Frequencies:

  • 500 Hz
  • 1,000 Hz
  • 2,000 Hz
  • 4,000 Hz

Test Storage: Up to 32 test records

Test Capture per Charge: Up to approximately 100 recordings

Display: 128 × 64 pixels

Display Format: Eight lines of 21 characters

Battery: Internal rechargeable NiMH battery pack

Battery Replacement: Not user replaceable

Charging-Cradle Power: 100–240 VAC, 50/60 Hz, 0.2 A

Warm-Up Period: None at room temperature

Device Dimensions: Approximately 230 × 115 × 70 mm

Device and Cradle Weight: Approximately 650 g / 1.43 lb

Safety Standard: IEC 60601-1

EMC Standard: IEC 60601-1-2

Performance Standard: IEC 60645-5, Type 2 tympanometer

Warranty: One-year manufacturer limited warranty

What Is Included

  • Welch Allyn MicroTymp 4 handheld tympanometer
  • MicroTymp 4 charging cradle
  • Charging-cradle power supply
  • Ear-tip starter kit
  • Four-volume test cavity
  • Probe-tip cleaning kit
  • USB data cable
  • Serial printer cable
  • MPT-II thermal printer kit
  • USB flash drive containing directions for use and TympView software
  • Product documentation

Compatible Accessories and Replacement Parts

  • 93710 MicroTymp 4 charging cradle
  • 93715 MicroTymp 4 power supply
  • 93720 MicroTymp 4 ear-tip starter set
  • 93730 MicroTymp 4 probe-tip cleaning kit
  • 93740 MicroTymp 4 probe-tip and gasket kit
  • 93750 MicroTymp 4 four-volume test cavity
  • 93760 MicroTymp 4 carrying case
  • 39410 MPT-II thermal printer kit
  • 39412 MPT-II thermal printer paper
  • 39414 MicroTymp 4 USB data cable
  • 39416 MPT-II replacement battery
  • Replacement single-use ear tips in multiple sizes

Frequently Asked Questions

What does the MicroTymp 4 measure?

It measures acoustic impedance or admittance in the external ear canal and provides objective information about tympanic membrane mobility and middle-ear function.

Does it perform tympanometry?

Yes. It measures tympanic peak pressure, peak admittance, ear canal volume, and tympanometric gradient and displays the resulting tympanogram.

Does it perform acoustic reflex testing?

Yes. It supports ipsilateral acoustic reflex testing at 500 Hz, 1,000 Hz, 2,000 Hz, and 4,000 Hz.

How quickly can it test a patient?

Each ear can be tested in as little as approximately three seconds after an adequate seal is obtained.

Can it be used for pediatric patients?

Yes. Current product information identifies the system for patients six months of age and older.

Does the system include a printer?

Yes. The 93700 configuration includes the MPT-II printer kit and printer cable.

Can results be transferred to a computer?

Yes. The system includes a USB data cable and TympView software for viewing, saving, and printing compatible results.

Can results be saved as a PDF?

Yes. TympView software supports saving a PDF copy of test results.

How many tests can be stored?

The device stores up to 32 test records internally.

How many tests can be performed on one charge?

The manufacturer lists up to approximately 100 recordings on a full charge.

Is the battery replaceable by the user?

No. The internal rechargeable NiMH battery pack is not intended to be replaced by the user.

Are ear tips reusable?

No. Compatible ear tips are single-use components and should not be reused between ears or patients.

Is an otoscopic examination required first?

Yes. The manufacturer identifies an illuminated otoscopic examination as an essential prerequisite before middle-ear testing.

Does the device require calibration?

The manufacturer recommends daily functional checks and annual calibration.

What warranty is included?

The MicroTymp 4 carries a one-year manufacturer limited warranty against defects in materials and workmanship, subject to the warranty terms.

Documents and Downloads

Welch Allyn MicroTymp 4 Product Brochure — PDF

https://www.hillrom.ca/content/dam/hillrom-aem/us/en/sap-documents/MRC/80023/80023853MRCPDF.pdf

Welch Allyn MicroTymp 4 Quick Guide — PDF

https://www.hillrom.ca/content/dam/hillrom-aem/us/en/sap-documents/LIT/80024/80024202LITPDF.pdf

Welch Allyn MicroTymp 4 User Manual — PDF

https://www.hillrom.ca/content/dam/hillrom-aem/us/en/sap-documents/LIT/80024/80024157LITPDF.pdf

MicroTymp 4 Probe-Tip Cleaning Guide — PDF

https://www.hillrom.ca/content/dam/hillrom-aem/us/en/sap-documents/LIT/80024/80024289LITPDF.pdf

TympView Software User Guide — PDF

https://www.hillrom.ca/content/dam/hillrom-aem/us/en/sap-documents/LIT/80024/80024346LITPDF.pdf